OSO Delta GEO DGC

- Heat pump cylinder with electric booster

The DELTA GEO is a purpose – designed heat pump ready unvented cylinder, provid­ing high heat pump input from the extremely large heating coil and substantial dedicated heat pump volume.

The Delta GEO cylinders carry ERP B rating. The cylinders have an electric immersion heater for boosting tempera­ture in the upper part of the cylinder. High performance fully flooded design, with expansion vessel and motorized valve supplied with the cylinder.

Heat pump installations using the OSO cylinders can be eligible for government backed Renewable Heat Incentive. Geo and DGC are ideal for connection with all single phase heat pumps up to 14 kW for a high performance system. 200 litre units are suitable for heat pumps up to 10 kW and have a 19 m coil. The positioning and size of the heat pump coil maximizes the use of air-source or ground-source energy from the heat pump.

An electric immersion heater is fitted in the top half of the cylinder for boosting the temperature, which, from the heat pump, is typically 50-60°C. The fully flooded design offers a superior hot water performance, and the separate external expansion vessel is supplied with wall bracket. The heating coil supports optimum heat transfer for heat pumps up to 14kW and is made from smooth pipe to prevent limescale accumulation.

The 25m length and 8 litre water content of the OSO heat pump coils give them superior heat transfer performance. Bosses and dry pockets are supplied for insertion of tem­perature sensor probes at low and high levels to interact with the Heat Pump.

Super Coil SC
Solarcyl RI SD
Technical Specifications
ERP

 

 

 
Prod. no. Product code Heat loss Capacity Vol@40°C Weight Coil rating Recovery time Volume Heat loss ErP Dia x Height
10221600 DGC200 - 3 kW/1X240V + coil 1.4m² 43 W 2.5 pers. 311 ltr. 44,3 Kg 26 Kw 14.6 min. 194 ltr. 1.032 kWh/d A Ø595x1270mm
10221700 DGC250 - 3 kW/1x240V + coil 1.8m² 47 W 2.5 pers. 412 ltr. 51,8 Kg 32 Kw 15.8 min. 245 ltr. 1.128 kWh/d A Ø595x1540mm
10221800 DGC300 - 3 kW/1x240V + coil 1.8m² 48 W 3.5 pers. 477 ltr. 58 Kg 32 Kw 18.3 min. 284 ltr. 1.152 kWh/d A Ø595x1750mm
Product Data Sheet
  - click to expand   - click to collapse
 
Description Unit
Actual capacity of the water tank at 20°C l 194 245 284
Outer diameter of the tank mm 595 595 595
Height of the appliance mm 1270 1540 1750
Gross weight of the appliance kg 44,3 51,8 58
Net weight of the appliance kg 40,7 48,1 53,2
Net weight of the appliance once filled with sanitary water kg 236,3 290,1 337,2
Material of the tank / integrated heat exchanger 1.4521 / 1.4521 or 1.4162 1.4521 / 1.4521 or 1.4162 1.4521 / 1.4521 or 1.4162
Material of element incoloy 825 incoloy 825 incoloy 825
Thermal insulation material PUR+VIP PUR+VIP PUR+VIP
Thermal insulation of the tank, average thickness mm 50 50 50
IP classification 21 21 21
Standby losses kWh/24h kWh/24h 1,032 1,128 1,152
Standby losses Watts Watts 43 47 48
Hot water capacity (1) >40°C Litres 311 412 477
Reheat time (1) (70%, lower/solar coil) min 14,6 15,8 18,3
Primary Heating Power (1) kW 26 32 32
Primary flowrate for Reheat time and Primary heating power l/h 900 900 900
Primary Heat exchanger pressure drop (1) mbar 44 44 44
ERP class A A A
Pressure information
Maximum design pressure of cylinder (rated pressure) MPa / Bar 1 / 10 1 / 10 1 / 10
Max. design pressure of heating coil MPa / Bar 1 / 10 1 / 10 1 / 10
Operating pressure of cylinder MPa / Bar 3,5 3,5 3,5
Operating pressure of heating coil MPa / Bar 2 2 2
Max. operating temperature of cylinder °C 70 70 70
Max. operating temperature on the heating coil °C 99 99 99
Expansion solution Aquasystem 3 Bar Aquasystem 3 Bar Aquasystem 3 Bar
Expansion Vessel Capacity l 18 24 24
Exchanger information
Primary Heat exchanger volume l 3,8 3,8 3,8
Primary Heat exchanger surface area 0,69 0,69 0,69
Ø Int. et Ø Ext. mm/mm ø20,4/ø22 ø20,4/ø22 ø20,4/ø22
Hydraulic connections
Secondary return mm 1/2 1/2 1/2
Primary heat exchanger flow inch 3/4" 3/4" 3/4"
Primary heat exchanger return inch 3/4" 3/4" 3/4"
Cold water inch 3/4" 3/4" 3/4"
Hot water inch 3/4" 3/4" 3/4"
Immersion heater inch 5/4" 5/4" 5/4"
Safety valve (factory fitted) inch 1/2 1/2 1/2
T & P Valve (factory fitted) inch 1/2" 1/2" 1/2"
Pressure reducing valve inch 3/4" 3/4" 3/4"
Temperature sensor sleeve diameter mm 8 8 8
Electrical characteristics
Supply voltage and frequency V/Hz 230/50 230/50 230/50
Current A 13 13 13
Power of the electrical resistance W 3000 3000 3000
Electrical installation IEEE regs IEEE regs IEEE regs
Thermostat type - immersion / cylinder Probe/Probe Probe/Probe Probe/Probe
Immersion capaticy Kw 3 3 3
Immersion heater - phase Phase Single Single Single
Immersion heater - voltage Volt 230/50 230/50 230/50
Immersion thermostat - temp range °C 18-70 18-70 18-70
Immersion thermostat - set temp °C 60 60 60
Indirect thermostat - temp range °C 25-65 25-65 25-65
Indirect thermostat - set temp °C 60 60 60
Safety
Safety valve opening pressure +/- 5% Bar 6 6 6
T & P valve opening pressure/temp Bar/°C 10/90 10/90 10/90
Safety thermostat cutout - immersion °C 87 87 87
Safety thermostat cutout - cylinder °C 80 80 80
Packaging
Width of box mm 610 610 610
Depth of box mm 610 610 610
Height of box mm 1320 1570 1780