OSO Ecoline GEO RI HP

  - Large capacity heating coil for heat pumps

The Ecoline Geo is a purpose-designed heat pump ready unvented cylinder, providing high heat pump input from the extremely large heating coil and substantial dedicated heat pump volume. The Ecoline Geo has an electric immersion heater for boosting temperature in the upper part of the cylinder. High performance fully flooded design, with expansion vessel supplied with the cylinder.

The Ecoline Geo is able to provide up to 60% of annual domestic hot water requirements from an air-source or ground-source heat pump. Heat pump installations using the Ecoline Geo can be eligible for government backed Renewable Heat Incentive.

Ecoline Geo is ideal for connection with all types of heat pumps up to 12 kW for a high performance system. Savings on hot water heating costs may depend on the type of heat pump use, but a typical installation will cover around 60 % of typical use.

 

The positioning and size of the coil in the Ecoline Geo maximizes the use of air-source or ground-source energy from the heat pump. An electric immersion heater is fitted in the top half of the cylinder for boosting the temperature, which, from the heat pump, is typically 50-60°C. The fully flooded design offers a superior hot water performance, and the separate external expansion vessel is supplied with wall bracket and flexible hose.

Key advantages:

  • Specifically designed for air-source or ground-source heat pumps up to 12 kW.
  • Immersion heater for boosting temperature from heat pump unit.
  • OSO ECO Foam insulation and 25 year guarantee.
Solarcyl RI SD
Solarcyl Twin Coil RI TC
Downloads
Technical Specifications
ERP
Choose volume

Ecoline Geo is only available in 1 volume for the time being.

 

 

 
Prod. nr. Product description Capacity Hot water - 40°C Heat-up (best) - 15°C - max. Recovery (best) - after 75% ERP Ratings Heat loss - 24 hours/W Dia x H mm.
RIHP250 3 kW/1x240V + coil 1,8m² 2-3 pers. 347 ltr. Heat Source Heat Source C 1,8 kWh/75W ø580x1400
RIHP300 3 kW/1x240V + coil 1,8m² 3-4 pers. 414 ltr. Heat Source Heat Source C 1.99 kWh/83W ø580x1600
Product Data Sheet
  - click to expand   - click to collapse
 
Direct Electric Unit Type Type    
Product Ecoline Geo RI HP 250 RI HP 300    
Produkt No. OSO no. 1 324 570 1 324 610    
Product Capacity Persons 2-3 3-4    
Product Segment   Domestic Domestic    
Product Cost Estimate - Rating - £/££/£££ OSO Standard £££ £££    
Product
Weight - Net kg 68 72    
Height - Max mm. 1400 1600    
Diameter mm. 580 580    
Volume - Actual ltr. 242 287    
Usable hot water draw off at 40°C (ltr) ltr. 347 414    
Heat Up - 1 element - 15°C - max Temp. minutes 94 136    
Heat Up - 2 elements - 15°C - max Temp. minutes - -    
Heat Up - Coil(s) - 15°C - max Temp. minutes Heat Source Heat Source    
Recovery - 1 elements after 75% draw off minutes 71 102    
Recovery - 2 elements after 75% draw off minutes - -    
Recovery - Coil(s) - 15°C - max Temp. minutes Heat Source Heat Source    
Standing Heat Loss - 24 hours kWh/24 hours 1,95 2,19    
Standing Heat Loss - Watts Watts 75 83    
ERP ratings C C    
Expansion Solution   External External    
Dimensions - Cardboard Box LxWxH mm. 585x585x1415 585x585x1620    
Volume - Cardboard Box 0.484 0.554    
Materials
Inner Cylinder Stainless Steel Duplex Duplex    
Coil(s) Stainless Steel Duplex Duplex    
Electric Element(s) Stainless Steel Incoloy 825 Incoloy 825    
Electric Box and Lid(s) Plastic V0 Plastic V0 Plastic    
Insulation PUR ECO Foam ECO Foam    
Outer Casing Steel Epoxy Coated Epoxy Coated    
Energy Source
Type - Primary   Heat Pump Heat Pump    
Type - Secondary   - -    
Temperature - Primary / Lower   Low Temp. Low Temp.    
Temperature - Secundary / Upper   - -    
Heating Coil(s)
Surface area - Primary / Lower 1,80 1,80    
Surface area - Secondary / Upper - -    
Dedicated Volume ltr. 142 157    
Recommended Flow Rate ltr./min. Heat Pump Heat Pump    
Electric
Immersion Heater - Capacity kW 3 3    
Immersion Heater - Phase Phase 1 1    
Immersion Heater - Voltage Volt 240 240    
Thermostat Type   Surface Surface    
Upper Working Thermostat - Temp. Range °C 40-70 40-70    
Upper Working Thermostat - Set Temp. °C 60 60    
Lower Working Thermostat - Temp. Range °C - -    
Lower Working Thermostat - Set Temp. °C - -    
Electrical Installation   IEEE regs IEEE regs    
IP Classification   IP 24 IP 24    
Connections
Cold Feed / Balanced Cold / Hot Water Compression 22mm 22mm    
Pressure Reducing Valve " (inches) 3/4 - Female 3/4 - Female    
Safety Valve " (inches) 3/4 - Male 3/4 - Male    
P&T Valve (factory fitted) " (inches) 1/2 - Male 1/2 - Male    
Drain Valve " (inches) 3/4 - Female 3/4 - Female    
Secondary Return   Use T-piece Use T-piece    
Immersion Heater(s) (factory fitted) " (inches) 5/4 - Male 5/4 - Male    
Expansion Vessel   External External    
Primary Flow / Return " (inches) 3/4 - Female 3/4 - Female    
Secondary Flow / Return " (inches) 3/4 - Female 3/4 - Female    
Sensor Connection " (inches) 1/2 - Female 1/2 - Female    
Safety
Safety Valve - Opening Pressure +/- 5 % Bar 8 8    
P&T Valve - Opening Pressure/Temp. Bar/°C 10/90 10/90    
Safety Thermostat - Cut-out Temp. °C 85 85    
Inner Cylinder - Design Pressure /Temp. Bar/°C 10/90 10/90    
Coil(s) - Design Pressure Bar 50 50    
Certifications / Approvals
Product Certifications Certificates CE / KIWA / WRAS
Manufacturing Plant Approvals Standards ISO 9001:2008 / ISO 14001:2008 / OHSAS 18001
Environment
Environmental Declaration 100 % Recyclable / >60 % Recycled Materials / Ozone Depletion Potential of 0 / Global Warming Potential of 1
Warranty - Water Quality EN 98/83EC
Water - Chloride Content Max - Cl ppm 250 250    
Water - Sulphate Content Max - So4 ppm 250 250    
Water - Chloride/Sulphate Content Max ppm 250 250    
Warranty Period - Inner Cylinder / Parts Years 25 / 2 25 / 2